Similar Projects
Last Updated | 05/25/2023 10:22 AM |
Project Title | Midway City Sanitary District Addition and Remodel |
Physical Address | View project details and contacts |
City, State (County) | Westminster, CA 92683 (Orange County) |
Category(s) | Commercial, Sewer and Water |
Sub-Category(s) | Office, Sewage Treatment Plant |
Contracting Method | Competitive Bids |
Project Status | Contract Award, Construction start expected August 2022 |
Bids Due | View project details and contacts |
Estimated Value | $5,499,483 [brand] Estimate |
Plans Available from | Architect |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | 1559547.2 o Interior Remodeling in the MCSD main office building, consisting of approximately 3,700 square feet. o Demolition of an existing 900 square foot out-building o Demolition of an existing 3400 square foot out-building o Interior Demolition of an existing single-occupancy restroom and rework to storage room. (Building C) o Construction of a 3,800 square foot office addition to the existing main office (Building A). o Construction of a new 940 square foot masonry Locker/Restroom building (Building B). o Coordination and Installation of temporary office trailers (including utility connection) and relocation of office furnishings from the main building to the trailers. o Underground conduit from main switchgear to future solar panel carport. o Installation of fire sprinklers in Buildings A and B. 3. General Work Description: o Interior Remodeling in the MCSD main office building, consisting of approximately 3,700 square feet. o Demolition of an existing 900 square foot out-building o Demolition of an existing 3400 square foot out-building o Interior Demolition of an existing single-occupancy restroom and rework to storage room. (Building C) o Construction of a 3,800 square foot office addition to the existing main office (Building A). o Construction of a new 940 square foot masonry Locker/Restroom building (Building B). o Coordination and Installation of temporary office trailers (including utility connection) and relocation of office furnishings from the main building to the trailers. o Underground conduit from main switchgear to future solar panel carport. o Installation of fire sprinklers in Buildings A and B. |
||||||||||||||||||||||||||||||||||||||||||||
Details |
|
||||||||||||||||||||||||||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||||||||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||||||||||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |