Similar Projects
Indefinite Delivery/Indefinite Quantity Electronic Security Systems (ESS) 7th Generation
Term Contract
Design
Less than $675,000,000 est. value

Council Chamber TV Lighting System
Alteration
Bidding
Titusville, FL

Rockledge ES Facility Renewal
Post-Bid
Rockledge, FL 32956

Specifications For Electrical Construction Repair To Damaged Utility Lines In Post Disaster Environment
Post-Bid
Moore Haven, FL

Replace Generators, South Substation (FAC 1395)
Results
$5,000,000 to $10,000,000 est. value
Patrick AFB, FL 32925

Replace Electric Transformers/Various
Results
$1,000,000 to $5,000,000 est. value
Patrick AFB, FL 32925

Generator Inspection, Maintenance, and Repair for Water Resources
Term Contract
Post-Bid
Titusville, FL 32796

Titusville Marina Wi-Fi Improvements
Results
Titusville, FL 32796

Hanger Fans
Term Contract
Post-Bid

ASCO 7000 Series Transfer Switch Replacement
Results
Cocoa, FL 32709

MATOC IDIQ for Control Systems Installations at Hydroelectric Facilities for The U.S. Army Corps of Engineers, South Atlantic Division
Term Contract
Post-Bid
Less than $20,000,000 est. value

Emergency Portable Generators
Term Contract
Results

Heavy Duty Safety Switch and Fuses
Alteration
Post-Bid
Cocoa, FL 32922

Small Generator (<350Kw) Preventative Maintenance & Repair Services - Term Contract
Term Contract
Results
Melbourne, FL

Storm Rates Overhead Line Construction 2022
Infrastructure
Post-Bid

Last Updated 04/12/2022 12:13 PM
Project Title

Replace Switchgear at the Booster Fabrication Facility, Kennedy Space Center, FL

Physical Address View project details and contacts
City, State (County) Cape Canaveral, FL   (Brevard County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value $5,000,000 to $10,000,000
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

The replacement of existing AFT Skirt Test Facility, L7-0251, electrical substation 1116A/B (MV Switch, transformers and secondary switchboard). The original building substation is approximately 25 years old and is obsolete. The new substation will be customized as a M-T-M (main-tie-main) configuration and will be customized to match the dimensions of the existing concrete pad and associated circuit conduits. The new substation will share a separate control panel that will contain integrated PLC controls. The replacement of existing Manufacturing Building, L6-0247, electrical substations 1114A/B & 1115A/B (MV Switch, transformers and secondary switchboard). The original building substations are approximately 25 years old and are obsolete. The new substations will be customized as a M-T-M configuration and will be customized to match the dimensions of the existing concrete pad and associated circuit conduits. The new substations will share a separate control panel that will contain integrated PLC controls. The replacement of existing Chiller Building, L6-0147, electrical substation 1113A/B (MV Switch, transformers and secondary switchboard). The original building substation is approximately 25 years old and is obsolete. The new substation will be customized as a M-T-M configuration and will be customized to match the dimensions of the existing concrete pad and associated circuit conduits. The new substationwill share a separate control panel that will have integrated PLC controls. Where used below, “removal” means selective demolition and potential storage of items removed, “replacement” means installation of new components/systems, and “reinstallation” means reuse of existing equipment removed and placed in a new configuration, as specified in contract documents to later be formally solicited. The work includes, but is not limited to, the following: Removal existing electrical equipment and Installation of new substations (switchgear/transformers/medium voltage switches), including installation of PLCs at locations inside the new substation, installation of PLC control and power wiring, installation of sensing devices, and connection to PLCs for the circuit. Existing equipment, components, assemblies, etc., that must be removed and replaced/reinstalled are known to have coatings containing or are partially comprised of asbestos, heavy metals, and/or PCBs. Abatement procedures will be required for certain construction activities. This project includes working in a fully operational facility that cannot have any significant duration of downtime without substantial coordination around launch, launch vehicle processing schedules, and testing and manufacturing related to various launch vehicles. Phasing of work around daily operations of the BFF AFT Skirt Test Facility, the Manufacturing and Chiller Building are critical to the success of the project. Daily coordination with operations personnel for outages and work in different areas will be required to keep the BFF buildings operational while performing the work specified in the contract documents.

Details

Division 02 - Existing Conditions.
Division 26 - Electrical, Medium-Voltage Switchgear, Low-Voltage Switchgear.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents