Similar Projects
18 N-12 HDPE IB/WT Double Wall 20
Post-Bid
Jacksonville, NC

Ductile Iron Wide Range Transition Coupling
Post-Bid
Jacksonville, NC

2019 Automated Meter Reading Project Phase III
Results
Jacksonville, NC 28540

4610--VHA Mar Cor Reverse Osmosis Water Purification BNOE | Sources Sought | 36U10120Q0029
Results

N-12 Hdpe Ib/Wt Double Wall N-12-FY22
Infrastructure
Post-Bid
Jacksonville, NC

Metron-Farnier T2-VNL-Paddle for Badger Plastic Residential Meters
Results
Less than $5,310 est. value
Jacksonville, NC 28541

Magnetic Flow Meter
Infrastructure
Post-Bid
Jacksonville, NC

3" Water Meter - Ultrasonic
Results
Jacksonville, NC 28541

Badger 1"Ultrasonic Water Meters
Results
Less than $1,920 est. value
Jacksonville, NC 28541

Badger 1-1/2" Ultrasonic Water Meters
Results
Less than $2,575 est. value
Jacksonville, NC 28541

Emergency Water System Connection - Tarawa Terrace
Results
Jacksonville, NC 28540

Badger M25 5/8" Water Meters
Results
Less than $3,550 est. value
Jacksonville, NC 28541

Badger 5/8" X 3/4" and 3" Ultrasonic Water Meters
Results
Less than $19,625 est. value
Jacksonville, NC

3 Ultrasonic Water Meter
Results
Less than $1,265 est. value
Jacksonville, NC

Badger M25 5/8 and M35 3/4 Water Registers
Results
Jacksonville, NC

Last Updated 10/28/2021 02:40 PM
Project Title

Water Systems Maintenance

Physical Address View project details and contacts
City, State (County) Camp Lejeune, NC   (Onslow County)
Category(s) Sewer and Water
Sub-Category(s) Water Lines
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

The scope of this project involves maintenance of two Hans Premium Water Model # 2 RO system due to AAMI TIR34 standards related to the water quality needed in a Sterile Processing Department (SPD). Due to the variance in test results for endotoxins and bacteria, it became apparent that the best possible corrective action was to install these Hans Premium Water Model # 2 RO systems. One was installed in the Endo Suite in Room W216 on the second floor and the other was installed in NHR165, HLD Mobile Unit. Prior to the Hans Premium Model # 2 installation, the SPD was dependent on the utility water entering the building. Due to multiple bad endotoxin and bacteria results, this system was purchased.

Details

Division 01 - General Requirements, Quality Control, Testing and Inspecting Services.
Division 33 - Utilities, Instrumentation and Control for Utilities, Water Utilities, Water Utility Distribution Piping, Water Utility Distribution Equipment, Disinfecting of Water Utility Distribution, Water Utility Storage Tanks.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents