Similar Projects
Last Updated | 01/21/2021 12:53 AM |
Project Title | Wingate Oaks Center - Smart Program Renovations |
Physical Address | View project details and contacts |
City, State (County) | Fort Lauderdale, FL 33311 (Broward County) |
Category(s) | Education |
Sub-Category(s) | Middle/Senior High School |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | $1,706,457 |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | SITE IMPROVEMENTS Complete installation of new fire alarm and removal of existing fire alarm system throughout campus. Existing fire alarm system to remain intact and functional until new system is fully operational and certified. New fire alarm system to be installed as per FFPC 2014. All new conduit and infrastructure to be concealed (surface mounted conduit and infrastructure will not be allowed). Contractor to repair, patch and paint all work related to F.A. installation and is to carry the repair, patch & paint to next adjacent vertical and/or horizontal break in the walls on either side and above and below works area. BUILDING # 1: • Re-roofing with new decking required** (Broward CPS) • Complete kitchen HVAC installation for non-a/c facility • Package roof top unit requires replacement • The chiller HVAC component is damaged requires replace • The exterior chiller HVAC requires replacement • Package roof top unit requires replacement • The air handler HVAC component requires replacement • The fan coil (chilled water) HVAC component requires replacement • The package unit HVAC component requires replacement • Duct cleaning required media center requires renovation provide renovation of RR associated with ed. adequacy renovation. BUILDING # 2 • Re-roofing with new decking required** (Broward CPS) • The exterior condenser requires replacement • The chiller HVAC component is damaged requires replace • The exterior chiller requires replacement BUILDING # 3 • Re-roofing BUILDING # 4 • Re-roofing with new decking required** (Broward CPS) • The exterior air handler HVAC component requires replacement • Ductwork requires replacement (sf basis) • The air handler HVAC component requires replacement BUILDING # 5 • Re-roofing with new decking required** (Broward CPS) • The fan coil HVAC component requires replacement |
||||||||||||||||||
Details |
|
||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |